Destroy ozone in process
A few days ago I made a few diagrams of typical uses of Ozone Destruct Units. I thought I would share them with you.

This diagram shows an example of the typical installation of the ODS-3H Ozone Destruct Unit. This destruct unit is placed on an Ozone Injection System to remove all ozone gas from the off-gas of the contact tank. All Ozone Systems never dissolve 100% of the ozone into the water, some ozone will escape. This ozone should be converted back to oxygen for safe operation.

This diagram shows an example of an Ozone Injection System used to fill a large water holding tank which is typical of many water treatment applications. It is important to note in applications such as these that the fill rate of the holding tank will displace air at a high rate. The Ozone Destruct Unit must be sized properly to be capable of this high air flow rate through the unit.

This diagram shows two possible uses of an ODS-2 Ozone Destruct Unit.
Ozone produced by an Ozone Generator and measured by a high concentration Ozone Analyzer must be catalyzed back to oxygen to be safely reintroduced into the ambient air.
Test chambers are commonly used to test various materials with high concentrations of ozone. The excess ozone from these chambers must be vented to have the ozone broken down to oxygen and then it can be safely vented into the atmosphere.
For more information about our Ozone Destruct line please contact us, we would be glad to help. View all our destruct units on our website. These diagrams and other information are also now on our website here.


Add A Comment