Low Concentration Ozone Analyzer

Inexpensive Ozone Analyzer

  • 0 - 100 PPM Range
  • 0.1 PPB resolution
  • proven high-accuracy UV-based Technology

Product ID: UV-106L        In Stock: Yes


UV-106L $4,195.00
Add DL-2 Data Logger for only $397.00.
Add Durable Carrying Case for only $295.00.
Add External Battery Pack for only $350.00.

Overview

The UV-106 Ozone Analyzer measures atmospheric ozone up to 100 ppm using the established technique of UV absorption at 254 nm. The instrument features high precision, small size and weight (4.3 lb, 2.0 kg), and low power consumption (3.5 Watt at 12 V DC) making it ideally suited for many remote field and urban network applications.

Specifications

Range 0 - 100 PPM Range
Resolution 0.0001 PPM (0.1 PPB)
Data Averaging Available Yes - 10-sec, 1-min, 5-min and 1-hr
Outputs Analog (0-2.5 V) of ozone concentration
Precision & Accuracy Greater of 2.0 ppb or 2% or reading
Units ppb, pphm, ppm, ug/m3 and mg/m3 (user selectable)
Sampling Mechanism Active Sampling with Internal Pump
Flowrate ~ 1 LPM
Internal Datalogger Yes - 14,336 data lines
Data Storage Duration 10 s avg = 1.4 days; 1 min avg = 8.5 days; 5 min avg = 42 days
Data Outputs RS-232, 0-2.5V Analog, LCD Display
Power Requirements 12 VDC, 3.5 W or 120/240 VAC
AC Adapter Included Yes - ready to use for 120/60Hz or 240V/50Hz Power
Dimensions 4 x 7.5 x 8.5-in HxWxD (10 cm x 19 cm x 22 cm)
Weight 4.3 lb (2.0 kg)

Support

Downloads

Frequently Asked Questions

Can the internal pump operate continuously?

Yes. The pump has a rated lifetime of 5,000 hours (7 months).

Can I use a different program than Hyper-terminal to collect the data?

Yes. A program called Tera-Term is available at the following website: http://hp.vector.co.jp/authors/VA002416/teraterm.html The Tera-Term program is preferred since Hyper-terminal only has a 500 line buffer limit.

Does elevation affect the accuracy of the ozone analyzer?

No. The accuracy of the analyzer will only vary 1-2 PPB for any elevation of 7,000-ft or less.

Is the ozone analyzer sensitive to other gases?

Yes. It is also sensitive to organics but low levels will not contribute significantly to interference. The general rule is that if you can smell the organic, then it may cause slight interference with the reading. Mild odors are typically not an issue. Chemicals like those commonly found in labs do not cause interference with the ozone analyzer.

How often does this monitor require calibration?

The manufacturer recommends a yearly calibration. The readings of all ozone monitors will start to stray over time and need to be corrected when possible.

Will I get a tracking number when my item ships?

For customers who chose UPS: a tracking number is automatically sent via e-mail before the order leaves our warehouse.

For customers who chose FedEx: a tracking number is usually available if requested by either e-mail or phone.

For customers who chose USPS: tracking numbers are only created by USPS for select services, such as insured packages. We will be happy to provide available tracking information if requested.

How often should the unit be re-zeroed?

Upon receipt of the UV-106, you should re-zero the unit so it is set properly for your location. The electronic zero of the instrument may be measured by attaching an ozone destruction cartridge to the air inlet for a period of 5-10 minutes.

For an accurate measurement, the instrument must have been turned on long enough for the internal temperature to stabilize. The observed offset, which can amount to ± a few ppb, can be corrected for by changing this calibration parameter from the front panel, as described below.

Because of noise and/or an inherent offset, some measured values will be below zero at very low ozone mixing ratios or while zeroing the instrument with an external scrubber. Also, the instrument zero may drift by a few ppb over time. For this reason, frequent zeroing of the instrument using an external ozone scrubber to determine the offset is recommended. If the instrument reads an average of 3 ppb with the external scrubber in place, the value of Z should be set to –3.

What type of serial (RS-232) cable do I need to connect my UV Analyzer to my computer's serial port?

For a serial connection, you will need a straight-through cable with female-to-female DB-9 connectors.

Accessories

Data Logging

Need to be able to log your ozone data? The DL-2 is a compatible data-logger that can be used to store and report ozone levels detected by the UV-106. The DL-2 is capable of storing 43,000 data points and be connected to your computer via the included USB Cable and easy-to-use Windows software.

Product ID: DL-2


DL-2 Data Logger $397.00

Carrying Case

The CUV-1 carrying case is tough and durable and will protect your monitor from drops, weather, and even travel wear.

Product ID: CUV-1


Carrying Case $295.00

Last Updated: February 8, 2012 3:17pm

The Web's Largest Supplier of Ozone Products

Partner Sites

We've updated this page and want to know what you think. For a $5 discount, take a look at the old version of this page and answer a few questions about it.