Groundwater Remediation System

Turnkey Ozone remediation System

Ozone Solutions can provide Cabinet Mounted Ozone Systems to meet your remediation needs. Ozone Productions up to 120 g/hr in one compact enclosure are possible. Up to 20 well outputs can be controlled by an easy to use HMI panel.

Features

  • Completely configurable to the customers needs
  • Completely customizable system to fit any needs
  • Ozone Generated from 90 % Oxygen
  • Up to 20 Well Outputs in One System
  • Cabinet systems sparge at up to 30 PSI
  • Initial breakthrough pressures of 50 PSI are possible
  • Very simple operation is completely automated, one touch startup and shutdown
  • Built in sensors for equipment and personnel safety
  • Optional manifold can be built in or separated
  • Manifold controlled with PLC and Human Interface Panel

Related Files

P&ID of System P&ID of System
119.1K
Flow Diagram and Explanation Flow Diagram and Explanation
71.2K
Product ID: Remediation Cabinet
Lead Time:4 weeks

Contact us for a custom quote today!

Specifications

Ozone Production:

10 - 120 g/hr ozone in one compact system

Ozone Concentration:

4-6% by weight

Sparge Air Flowrate

Up to 2.5 CFM to each well

Oxygen Purity:

All ozone generated from 90% pure oxygen

Delivery Pressure:

30 PSI Constant Sparge Pressure (50 PSI momentary breakthrough pressure)

<u>SAFETY AND ENVIRONMENTAL SENSORS</u>

<u>SENSOR FUNCTION</u>

Ozone Sensor

Detects ozone leaks and shuts down system

Dew Point Sensor

Detect dew point of dry air to protect the O2 Concentrator and O3 Generator

Relative Humidity Sensor

Monitors Humidity of ambient air to protect the air dryer

Temperature Sensor

Monitors temperature inside the ozone system to protect all equipment

Pressure Sensor #1

Ensures incoming pressure is sufficient

Pressure Sensor #2

Ensures Oxygen Pressure is sufficient

Other Sensors are available:

Ozone output analyzer % by weight, Oxygen Sensor, or any other sensor necessary

Outputs:

Each sensor will set a fault light visible on the controller, close dry contacts available in the controller, and give mV or mA output signals

Manifold:

Optional, any number of wells set in groups or with individually, all manifolds can be manually controlled or controlled with a PLC and HMI Panel

Air Conditioner:

Top Mount 2300 BTU standard, 4500 BTU air conditioner will be used with higher ozone production units

Power Requirements

120V 1 phase 20 Amp Circuit,

Dimensions (W x D x H)

50-in x 20-in x 60-in (size may change with certain options)

Weight

440 lbs