Groundwater Remediation System
Turnkey Ozone remediation System
Ozone Solutions can provide Cabinet Mounted Ozone Systems to meet your remediation needs. Ozone Productions up to 120 g/hr in one compact enclosure are possible. Up to 20 well outputs can be controlled by an easy to use HMI panel.
Features
- Completely configurable to the customers needs
- Completely customizable system to fit any needs
- Ozone Generated from 90 % Oxygen
- Up to 20 Well Outputs in One System
- Cabinet systems sparge at up to 30 PSI
- Initial breakthrough pressures of 50 PSI are possible
- Very simple operation is completely automated, one touch startup and shutdown
- Built in sensors for equipment and personnel safety
- Optional manifold can be built in or separated
- Manifold controlled with PLC and Human Interface Panel
Related Files
|
|
P&ID of System |
| 119.1K | |
|
|
Flow Diagram and Explanation |
| 71.2K |
| Product ID: | Remediation Cabinet | |
| Lead Time: | 4 weeks |
Contact us for a custom quote today!
Specifications
Ozone Production: | 10 - 120 g/hr ozone in one compact system |
Ozone Concentration: | 4-6% by weight |
Sparge Air Flowrate | Up to 2.5 CFM to each well |
Oxygen Purity: | All ozone generated from 90% pure oxygen |
Delivery Pressure: | 30 PSI Constant Sparge Pressure (50 PSI momentary breakthrough pressure) |
<u>SAFETY AND ENVIRONMENTAL SENSORS</u> | <u>SENSOR FUNCTION</u> |
Ozone Sensor | Detects ozone leaks and shuts down system |
Dew Point Sensor | Detect dew point of dry air to protect the O2 Concentrator and O3 Generator |
Relative Humidity Sensor | Monitors Humidity of ambient air to protect the air dryer |
Temperature Sensor | Monitors temperature inside the ozone system to protect all equipment |
Pressure Sensor #1 | Ensures incoming pressure is sufficient |
Pressure Sensor #2 | Ensures Oxygen Pressure is sufficient |
Other Sensors are available: | Ozone output analyzer % by weight, Oxygen Sensor, or any other sensor necessary |
Outputs: | Each sensor will set a fault light visible on the controller, close dry contacts available in the controller, and give mV or mA output signals |
Manifold: | Optional, any number of wells set in groups or with individually, all manifolds can be manually controlled or controlled with a PLC and HMI Panel |
Air Conditioner: | Top Mount 2300 BTU standard, 4500 BTU air conditioner will be used with higher ozone production units |
Power Requirements | 120V 1 phase 20 Amp Circuit, |
Dimensions (W x D x H) | 50-in x 20-in x 60-in (size may change with certain options) |
Weight | 440 lbs |