Ozone Disinfection / Ozone Contact Time Kinetics

Water is disinfected but never completely sterilized in the water treatment process. This disinfection is a two part process that includes:

  1. Removal of particulate matter by filtration. A rule of thumb is that high turbidity in the effluent is a potential health risk, because viruses and bacteria can hide within the rough texture of particulates. Therefore, removal of the particulates reduces the chance of pathogenic microorganisms in the effluent. (Refer to Figure 1)

  2. Figure 1:
    Simplified Diagram of a Pathogen Encapsulated by a Particulate

    Simplified Diagram of a Pathogen Encapsulated by a Particulate

    Courtesy of Eric Karch and David Loftis

  3. Inactivation of pathogenic microorganisms by chlorine, chlorine dioxide, ozone, or other disinfectants:

    Contact time and kinetics are simply a measure of the inactivation due to time and concentration of the disinfectant. The USEPA has developed regulations for the minimum kill percentages (inactivation) necessary for public water to be considered potable. These regulations include a minimum disinfection of:

    • Three log (99.9%) for Giardia lamblia cysts
    • Four log (99.99%) for enteric viruses

In “water treatment terms” 1 log inactivation is referred to as 1 credit inactivation. Different types of filtration are assigned certain removal credits. For example, conventional filtration is worth 2.5 credits for Giardia cysts. Since the EPA requires 3 log (credit) removal, an additional 0.5 credit inactivation from disinfection must be attained.

Varying degrees of disinfection can be attained by altering the type and concentration of disinfectant, as well as the time water is in contact with the disinfectant. The decision to use one type of disinfectant versus another will set the precedence for the remainder of the values needed to attain the proper disinfection. The time untreated water is exposed to the disinfectant and the concentration of that disinfectant are the main factors in the equation that will be discussed in the next section. [Notice that the units of contact time are (mg/l)(min).]

Relationship Between Kill Efficiency and Contact Time

Figure 2:
Graphical Representation of Chick's Law

Graphical Representation of Chicks Law

Taken from R.C. Hoen's CE 4104 Spring Notes.

A relationship between kill efficiency and contact time, was developed by Harriet Chick while she was a Fellow in the Pasteur institute in Paris, France. The research yielded data supporting her relationship that is shown in Figure 2. (No) represents the initial number of organisms and N is the number of organisms at time t. As contact time between water and disinfectant increases, the ratio of No/N decreases as Chick's Law predicts.

Figure 2 Formulas

Factors Affecting C*t Values