PortaSens II
Handheld Ozone Detector
The Series C16 PortaSens II portable gas leak detector is a versatile tool for performing regular leak checks in gas storage areas, around process equipment and piping, or in confined spaces prior to entry. Designed for easy one-hand operation, the detector contains an internal sample pump and a flexible sampling wand to allow pinpoint location of the source of leakage. A large character display insures that measured values are easily visible, and a back-light for the display insures readability in low or no light conditions.
Features
- Internal sample pump and external sampling wand
- One-hand pistol grip design
- Standard "D" cell battery and rechargeable backup battery
- Easy to read back-lit graphics liquid crystal display
- Instantaneous and timed-sampling modes of operation
- Visual and Audible alarms
- Internal data-logger with RS-232 output
Related Files
|
|
C16 User Manual |
| 221.1K | |
|
|
Information Sheet |
| 494.1K | |
|
|
How to Find Ozone Leaks |
| Product ID: | C16 | |
| In-stock: | yes | |
| Price: | $1,595.00 |
220V Power Option
220V/50Hz Power Option necessary for overseas use.
| Item | Price | |
|---|---|---|
| 220V/50Hz Power Option | $20.00 |
Serial to USB Adapter
Connect your C16 monitor to your computer using the provided RS-232 cable and this USB adapter cord.
| Item | Item | |
|---|---|---|
| RS-232 to USB Adapter | $37.00 |
Specifications
Range | |
Standard Range | 0-2 PPM |
Optional Range | 0-20 PPM |
Accuracy | |
0-2 ppm sensor | +/- 10% |
0-20 ppm sensor | +/- 10% |
Resolution | |
0-2 ppm sensor | 0.01 ppm |
0-20 ppm sensor | 0.1 ppm |
Sensor type | Electrochemical |
Display | Back-lit graphics liquid crystal display |
Alarms | Three concentration alarms (caution, warning, and alarm with adjustable setpoints). Low flow and low battery alarms. Alarms displayed on LCD & indicated by audible beeper. |
Outputs | RS-232 output of stored gas values. 0-1 VDC analog (requires optional output cable) |
Datalogging | 12,000 data points. Programmable from 1-60 minutes. Capacity: 8 days at 1 minute storage intervals. |
Temperature range | -13 to +131 F (-25 to +55 C) |
Humidity range | 0-95% Non-condensing |
Battery | D cell battery, alkaline recommended, 75 hours operation. Internal rechargeable battery for backup power, 6 hours operation. 115 or 220 VAC chargers available. |
Power requirements | D cell battery, alkaline recommended, 75 hours operation. Internal rechargeable Nicad for backup power, 6 hour operation. 115 or 220 VAC chargers available. |
Size | 3.5"(W) x 9"(H) x 5.5"(D) or 89mm x 229mm x 140mm |
Weight | 7 lbs. (3.2 Kg.) |
Supporting documents | User manual and NIST Traceable Calibration Sheet included |
Warranty | 1 yr |
Sensitivity | 1% of sensor module range |
Detector Material | Glass Filled Polycarbonate |